Assessment of energy and angular dependence of LiF:Mg,Ti dosimeters irradiated in the quantity Hp(0.07)
DOI:
https://doi.org/10.15392/2319-0612.2023.2142Keywords:
Dosimetry, extremidade, Hp(0.07)Abstract
Radiation dosimetry has the purpose of quantifying the dose received by the occupationally exposed individual. The device used in this process is called a dosimeter, the dosimeter can be used in different situations, for example, the dosimeter used to quantify the dose received in the fingers is the ring model dosimeter, for the extremity, which is the focus of this work. In Brazil, we still do not have standards for the calibration of extremity dosimeters, therefore, in this work, the CASEC recommendations were used, adapted for extremity dosimetry. For a dosimeter to be used in its respective routine, it must present results within some pre-established limits in reference standards. For this purpose, energy dependence and angular dependence tests were carried out. To calibrate the LiF:Mg,Ti thermoluminescent dosimeters, a phantom rod was used. The phantom rod has the function of simulating the region of interest, in the case of this work, the fingers. The dosimeters were irradiated in the magnitude Hp(0.07), with the doses and energies recommended by the CASEC standard. The aim of this work is to characterize end dosimeters in the ring model with LiF:Mg,Ti detectors.
Downloads
References
NASCIMENTO, G. et al. Characterization and calibration of thermoluminescent dosimters of LiF: Mg, Ti in the quantity Hp (0.07), INAC, 2021.
ICRP, International Commission on Radiological Protection. The recommendations of the Internation Commission on Radiological Protecion. Publication 103, 2007.
SQUAIR, P. L., NOGUEIRA, M. S., OLIVEIRA, P. M. C. Calibração e Caracterização de Dosímetros de Extremidade. Santos, INAC, 2005.
CASEC, Comitê de Avaliação de Serviços de Ensaio e Calibração, Desempenho de Monito-ração Individual – Critérios e Condições, 2013.
OKUNO, Emico; YOSHIMURA, Elisabeth Mateus. Física das radiações. Oficina de Textos, 2016.
Harshaw-Bicron, model 4500 TLD Workstation Operators Manual, Publication N°4500-0- 0-0598-002, 1998.
ICRU, International Commission on Radiation Units and Measurements, Measurement of Dose Equivalent from External Photon and Electron Radiation, Report 47, 1992.
Published
Issue
Section
Categories
License
Copyright (c) 2023 Brazilian Journal of Radiation Sciences
This work is licensed under a Creative Commons Attribution 4.0 International License.
Licensing: The BJRS articles are licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/