Computational model of a 3D dosimetry system - ArcCHECK®
DOI:
https://doi.org/10.15392/bjrs.v7i2A.675Palavras-chave:
ArcCHECK, Monte Carlo simulation, Dosimetry, Quality Assurance, RadiotherapyResumo
Ionizing radiation therapies have been improving over the years, becoming more specific for each patient. Thereby, as the treatment planning system (TPS) complexities increases, the quality assurance (QA) methods have to be in constant evolution. One of the techniques that demand great complexity is the Volumetric Modulated Arc Therapy (VMAT), and one possible way to VMAT commissioning is using 3D dosimetry systems. Recently a new 3D dosimetry system called ArcCHECK had been developed and commercialized mainly for VMAT quality assurance. It is water-equivalent and composed by an array of 1386 diodes arranged in a helical pattern. Since simulation methods, like Monte Carlo method, ensure highly accurate results, MCNP (A General Monte Carlo N-Particle Transport Code System) is totally reliable for problems that involve radiation transport. This work presents two computational models for Monte Carlo simulations to predict detection responses in the QA procedure using the ArcCHECK. The computational models were validated comparing the system responses obtained from MCNP6 simulations against measured responses due to a 6 MeV clinical photon beam from a Linear Accelerator. 2D dose maps were reported here with good agreement between simulated and measured values.Downloads
Referências
FEYGELMAN, V.; ZHANG, G.; STEVENS, C.; NELMS, B. E. Evaluation of a new VMAT QA device, or the “X” and “O” array geometries. Journal of Applied Clinical Medical Physics, v. 12, n. 2, 2011.
OTTO, K. Volumetric modulated arc therapy: IMRT in a single gantry arc. Med. Phys., 35(1), p. 310 – 317, 2008.
SURUCU, M.; YEGINER, M.; KAVAK, G. O.; FAN, J.; RADOSEVICH, J. A. ; AYDO-GAN, B. Verification of dose distribution for volumetric modulated arc therapy total marrow irradi-ation in a humanlike phantom, Med. Phys., v. 39, p. 281 – 288, 2012.
GONÇALVES, L. R.; SANTOS, G. R.; MENEGUSSI, G.; SILVA, M. A.; PÁSSARO, A. M.; RODRIGUES, L. N. Comissionamento de um acelerador linear para realização da radioterapia em arco modulada volumetricamente, Revista Brasileira de Física Médica, 7(2), p. 65 – 70, 2013.
Sun Nuclear Corporation. ArcCHECK Reference Guide: The Ultimate 4D QA Solution. Melbourne, Florida, United States, 2012.
YORIYAZ, H. Método de Monte Carlo: princípios e aplicações em Física Médica. Revista Brasileira de Física Médica, 3(1), p. 141 – 149, 2009.
Pelowitz, D. B. MCNP6 User’s Manual. Version 1.0, LA-CP-13-00634, Los Alamos Nati-onal Laboratory, 2013.
RUCCI, A.; CARLETTI, C.; CRAVERO, W.; STRBAC, B. Use of IAEA’s phase-space files for the implementation of a clinical accelerator virtual source model. Physica Medica, v. 30, p. 242 – 248, 2014.
RUCCI, A.; CARLETTI, C.; CRAVERO, W.; STRBAC, B. Use of IAEA’s phase-space files for virtual source model implementation: Extension to large fields. Physica Medica, v. 32, p. 1030 – 1033, 2016.
The MathWorks Inc. MATLAB and Statistics Toolbox Release R2015a. Natick, Massa-chusetts, United States, 2015.
Downloads
Publicado
Edição
Seção
Licença
Direitos autorais (c) 2021 Brazilian Journal of Radiation Sciences

Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.
Declaro que o presente artigo é original, não tendo sido submetido à publicação em qualquer outro periódico nacional ou internacional, quer seja em parte ou em sua totalidade. Declaro, ainda, que uma vez publicado na revista Brazilian Journal of Radiation Sciences, editada pela Sociedade Brasileira de Proteção Radiológica, o mesmo jamais será submetido por mim ou por qualquer um dos demais co-autores a qualquer outro periódico. Através deste instrumento, em meu nome e em nome dos demais co-autores, porventura existentes, cedo os direitos autorais do referido artigo à Sociedade Brasileira de Proteção Radiológica, que está autorizada a publicá-lo em meio impresso, digital, ou outro existente, sem retribuição financeira para os autores.
Licença
Os artigos do BJRS são licenciados sob uma Creative Commons Atribuição 4.0 Licença Internacional, que permite o uso, compartilhamento, adaptação, distribuição e reprodução em qualquer meio ou formato, desde que você dê o devido crédito ao (s) autor (es) original (is) e à fonte, forneça um link para a licença Creative Commons, e indique se mudanças foram feitas. As imagens ou outro material de terceiros neste artigo estão incluídos na licença Creative Commons do artigo, a menos que indicado de outra forma em uma linha de crédito para o material. Se o material não estiver incluído no licença Creative Commons do artigo e seu uso pretendido não é permitido por regulamentação legal ou excede o uso permitido, você precisará obter permissão diretamente do detentor dos direitos autorais. Para visualizar uma cópia desta licença, visite http://creativecommons.org/licenses/by/4.0/